Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioorg Med Chem Lett ; 26(21): 5164-5167, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27720549

RESUMO

Monocyclic analog of neuroexcitatory neodysiherbaine has been designed and stereoselectively synthesized in 0.40% yield over total 24 steps starting from d-ribose, by employing domino aldol-Cannizzaro reaction and stereoselective aldol reaction for construction of two quaternary carbon stereogenic centers at C4 and C6 positions, respectively. The hyperactivity of neodysiherbaine in mice was found to deteriorate in the novel analog, upon intracerebroventricular injection.


Assuntos
Alanina/análogos & derivados , Compostos Bicíclicos Heterocíclicos com Pontes/síntese química , Alanina/síntese química , Alanina/química , Alanina/farmacologia , Animais , Compostos Bicíclicos Heterocíclicos com Pontes/química , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Relação Dose-Resposta a Droga , Avaliação Pré-Clínica de Medicamentos , Espectroscopia de Ressonância Magnética , Camundongos , Relação Estrutura-Atividade
2.
J Oncol Pharm Pract ; 18(2): 201-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21947739

RESUMO

PURPOSE: Cyclophosphamide (CP) contamination has been detected in Japanese hospitals. In other countries, the surface contamination of CP vials has been reported; however, the manufacturing process of Japanese CP vials is unknown, so the conditions are not necessarily the same as in other countries. This study aimed to establish whether vial surface contamination also occurs in Japan. METHOD: Contamination of vial surfaces was examined with a wipe test. Urine samples were taken from a pharmacist, engaged solely in dispensing work, for 29 h. It was also investigated whether CP vials were dispensed during the urine sampling period. In addition, vial surfaces, purposely coated with CP and then washed, were examined using wipe tests. RESULT: CP was detected at 30-60% in vials, which was 11-62 ng (0.10-0.54 ng/cm(2)). One of the urine samples was contaminated (CP 13.5 ng); this was taken on Day 2 (11:35 AM). CP was not detected among the washed vials. DISCUSSION: This study shows that the surface of Japanese CP vials was contaminated and that it was probable that healthcare workers were exposed to CP. CP absorption by the pharmacist was probably due to dermal uptake while dispensing. Washing the vial is considered effective to avoid CP exposure. Manufacturers should be more proactive to prevent contamination and healthcare workers should comply with exposure prevention rules. Cytotoxic drugs should be included in institution monitoring lists.


Assuntos
Ciclofosfamida/urina , Embalagem de Medicamentos , Monitoramento Ambiental/métodos , Exposição Ocupacional/análise , Farmacêuticos , Ciclofosfamida/análise , Embalagem de Medicamentos/normas , Monitoramento Ambiental/normas , Humanos , Japão , Farmacêuticos/normas , Reprodutibilidade dos Testes , Propriedades de Superfície
3.
J Oncol Pharm Pract ; 17(1): 55-60, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20605849

RESUMO

PURPOSE: Three products can be used in Japan for the reconstitution of cytotoxic agents: PhaSeal, Chemo CLAVE and Chemo Mini Spike (CMS). The low preparation volume may be affected by residual-related volume in their devices. In this study, the residual-related error in their devices was examined and compared. METHOD: The blank of each component of these devices was weighed using a precision electric balance. After ejecting distilled water (DW) for injection, each was weighed again with the balance. In addition, for etoposide in the cases of PhaSeal and Chemo CLAVE, the components of the devices were similarly weighed. RESULT: The weight gains of each device after ejecting DW were as follows: CMS-V (440 mg) greater than the combined components of Chemo CLAVE (128-171 mg)/CMS-MT (123 mg) greater than the combined components of PhaSeal (13-56 mg). For etoposide, the weight gains of PhaSeal (208 mg) and Chemo CLAVE (223 mg) showed no significant difference. The priming volume of each device was calculated from the specific gravity of water. The residual-related volume was 'CMS-V > Chemo CLAVE, CMS-MT > PhaSeal', although this was very slight in actual situations. CONCLUSION: The residual-related volume was marked in its low preparation volume. In water-soluble drugs, the residual volume of PhaSeal was lowest of the devices in this study, but in viscous drugs, such as etoposide, the residual volume of PhaSeal was almost identical to Chemo CLAVE; that is, the residual volume of these devices was affected by the solution property. The residual-related volume in the devices will lead to errors; therefore, residual-related errors need to be considered in the use of these devices.


Assuntos
Antineoplásicos/normas , Exposição Ocupacional/prevenção & controle , Equipamentos de Proteção , Antineoplásicos/química , Composição de Medicamentos/instrumentação , Composição de Medicamentos/métodos , Desenho de Equipamento , Falha de Equipamento , Humanos , Japão , Solubilidade , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...